FCAW
DW-55LSR
Flux cored wire
| Features: | - Excellent impact value down to -60°C in the as-welded and PWHT conditions
|
|---|
| Classification: | AWS A5.29 E81T1-K2C |
|---|
| Shielding gas: | CO2 |
|---|
| Polarity: | DCEP |
Welding Positions:
Packaging data
| φ mm | Spool |
| 1.2 | 12.5kg | 15kg | 20kg |
| Volume mm | 300W, 110H, 300L |
Composition (all-weld metal mass %)
| | Typical | Guarantya |
| C | 0.06 | 0.15 |
| Si | 0.29 | 0.80 |
| Mn | 1.21 | 0.50-1.75 |
| P | 0.008 | 0.030 |
| S | 0.007 | 0.030 |
| Ni | 1.56 | 1.00-2.00 |
| Cr | 0.01 | 0.15 |
| Mo | 0.01 | 0.35 |
| V | <0.01 | 0.05 |
| Note: aSingle values are maximium. |
Welding parameters (A)
| φ mm | 1F, 1G, 2F | 2G | 3G uphill, 4G |
| 1.2 | 150-300 | 150-280 | 150-250 |
All-weld mechanical properties
| | Typical | Guaranty |
| 0.2%YS (MPa) | 480 | 440 | 469min. |
| TS (MPa) | 565 | 530 | 552-689 |
| EI on 4d (%) | 33 | 34 | 22min. |
| IV -60°C (J) | 115 | 100 | 27min. |
| PWHT (°Cxh) | AW | 620x1 | AW |
| ABS | 5YQ420SA (H5) 4Y400SA (H5) |
| LR | 5Y42S, MG, H5 |
|---|
| DNL | ⅤY42MS (H5), MG VL2-4L, 4-4L
|
| BV | SA4Y40M, UP, H5
|
|---|
| NK | MG(KSW5Y42G (C) H5)
|